SMS: NULL Data Values Reported Differently by INVDOS & INVWIN32

ID: Q191437

The information in this article applies to:

SYMPTOMS

The data reported for common properties by INVWIN32 does not match the data reported by INVDOS.

INVDOS reports None if there is no data for certain fields and INVWIN32 reports a blank value if there is no data for certain fields.

There are certain properties that differ:

   Files Not Installed
   System Files Not Modified
   Failed Hardware Checks

The differing methods of reporting null data may lead to difficulties generating queries in the Systems Management Server Administration User interface.

Queries to return all data must include both None and a space, for example:

   'None'

   -or-

   ' '

STATUS

Microsoft has confirmed this to be a problem in Systems Management Server version 1.2. This problem has been corrected in the latest U.S. service pack for Systems Management Server version 1.2. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

   S E R V P A C K

Additional query words: prodsms SP SP4
Keywords          : kbfix1.20.sp4 kbbug1.20 
Version           : WinNT:1.2
Platform          : winnt
Issue type        : kbbug
Solution Type     : kbfix

Last Reviewed: September 9, 1998