FIX: Read Instance on a Collection Fails to Produce Collection List

ID: Q235834


The information in this article applies to:


SYMPTOMS

When viewing a collection through the Systems Management Server Administrator Console, a user may not be able to see members of that collection, even though the user has been granted explicit READ instance rights to that collection. In addition to granting a user READ rights to a named collection, the READ RESOURCE right must also be granted in order for a result list to be produced. This workaround is necessary only prior to Systems Management Server Service Pack 1 (SP1). After the application of SP1 it is only necessary to add READ instance permissions to the collection.


RESOLUTION

Microsoft has confirmed this to be a problem in Systems Management Server version 2.0. This problem has been corrected in the latest U.S. service pack for Systems Management Server version 2.0. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


STATUS

Microsoft has confirmed this to be a problem in Systems Management Server version 2.0. This problem has been corrected in the latest U.S. service pack for Systems Management Server version 2.0. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words: prodsms sms collection permissions


Keywords          : kbSecurity kbSMS200 kbSMS200bug kbSMS200fix kbCollections 
Version           : winnt:2.0
Platform          : winnt 
Issue type        : kbbug 

Last Reviewed: July 9, 1999