SMS: Remote Control WinNT to WinNT Gets Out of Synch and Drops ConnectionID: Q233545
|
When you take Remote Control of a Windows NT Workstation computer from another computer that is running Windows NT, the UDP packets appear to get out of synchronization. After a few minutes, the client no longer receives input from the administrator. The administrator can still see the client mouse and keyboard input, but can no longer update the client. The administrator keyboard and mouse are non functional at that point.
A supported fix that corrects this problem is now available from Microsoft, but
it has not been fully regression tested and should be applied only to systems
experiencing this specific problem. If you are not severely affected by this
specific problem, Microsoft recommends that you wait for the next Systems Management Server service pack
that contains this fix.
To resolve this problem immediately, contact Microsoft Product Support Services
to obtain the fix. For a complete list of Microsoft Product Support Services
phone numbers and information on support costs, please go to the following
address on the World Wide Web:
http://www.microsoft.com/support/supportnet/overview/overview.aspThe English version of this fix should have the following file attributes or later:
Date Time Version Size File name Platform
-----------------------------------------------------------------
4/2/99 7:22PM 1.2 326 KB Sightnt.dll Intel
5/21/99 1:25PM 1.2 167 KB Wuser32.exe Intel
4/2/99 7:23PM 1.2 635 KB Sightnt.dll Alpha
5/21/99 1:25PM 1.2 339 KB Wuser32.exe Alpha
Q154871 Determining If You Are Eligible for No-Charge Technical Support
Microsoft has confirmed this to be a problem in Systems Management Server version 1.2.
Additional query words: prodsms remotecontrol rc admin machine rem synch sync