ID: Q186408
The information in this article applies to:
Under specific circumstances, when you attempt to upgrade a secondary site, the upgrade may fail because of timing-related issues. This may occur in environments where there are several secondary site servers under the central site, and each secondary site has numerous logon servers.
During a secondary site upgrade process, the Upgrade Bootstrap Service is delivered to the secondary site server and started. This issues a site shutdown using a SHUTDOWN.CT1.
Note that the shutdown may take an inordinate amount of time because of the number of logon servers.
During this time, the parent site's Hierarchy Manager Service sends the site install package. The Systems Management Server Despooler Service is still active at the secondary site server because it has not shut down, and it records the following error message:
Executing instruction of type MICROSOFT|SMS|MINIJOBINSTRUCTION|CONFIG
Cannot find config mini inst specific data
Despooler failed to execute the instruction, error code = c0000001
The secondary site never upgrades, it simply goes into an Emergency Restart
after 48 hours.
To work around this problem, force an upgrade of the secondary site from its parent site using the PREINST Command:
PREINST /UPGRADE:SecondarySiteCode
Microsoft has confirmed this to be a problem in Microsoft Systems Management Server version 1.2. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
Additional query words: prodsms
Keywords : smssetup kbbug1.20 smshierman smssiteconfigman
Version : WINDOWS:1.2
Platform : WINDOWS
Issue type : kbbug
Solution Type : kbpending
Last Reviewed: August 15, 1998