SMS: Edit .ini File Fails on Win95/98 if Compiled with '32-Bit Only'ID: Q235728
|
When using Microsoft Systems Management Server Installer version 2.0 to compile a script with the Edit INI File action included in it, the action might fail if the script is run on a Microsoft Windows 95 or a Microsoft Windows 98 system.
This will occur if the script was compiled using the Microsoft SMS Installer 32 and it was compiled only for 32-bit clients. The option to compile only for 32-bit clients is selected under installation properties\destination platforms in the script editor.
Select both 16-bit and 32-bit under installation properties\destination platforms in the script editor before compiling the executable.
Microsoft has confirmed this to be a problem in Systems Management Server Installer version 2.0. This problem has been corrected in the
latest U.S. service pack for Systems Management Server Installer version 2.0. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: prodsms
Keywords : kbSMS200 kbSMS200bug smsinst
Version : WINDOWS:2.0; winnt:2.0
Platform : WINDOWS winnt
Issue type : kbbug
Last Reviewed: July 9, 1999