SMS: Software Metering Server Fails to Complete InstallationID: Q227020
|
In Systems Management Server version 2.0, when you install the Software Metering components, the installation may fail if the NTFS drive from which the files are being installed is compressed.
If you enable logging, this failure is logged in the Licsvcfg.log file located in the \SMS\LOGS folder. Log entries include the following error message:
The \\<server>\LicMtr share is created but no files are successfully copied. During license server manager cleanup, the LicMtr share is removed.Copying C:\SMS\bin\i386\ProductDB.Dll to \\<server>\LicMtr\ProductDB.Dll...
The file installation failed. The license server manager is attempting to clean up the target server.
Microsoft has confirmed this to be a problem in Systems Management Server version 2.0. This problem has been corrected in the
latest U.S. service pack for Systems Management Server version 2.0. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: prodsms
Keywords : kberrmsg kbsetup kbSMS200 kbSMS200bug
Version : winnt:2.0
Platform : winnt
Issue type : kbbug
Last Reviewed: July 14, 1999