XFOR: Microsoft Exchange CCMC Shuts Down and Logs Events 82 and 83ID: Q176375
|
The Microsoft Exchange Server Connector for Lotus CC-Mail (CCMC) logs
the following events in the Windows NT Event Viewer:
Event ID 82
An exception has occurred. The information is as follows:
Exception code c0000005. Exception flags: 0. Exception address 2e3d3d3d.
Number of parameters: 2. Exception information 0 2e3d3d3d.
Event ID 83:
The exception UNKNOWN was caught in function dwCCExport.
Event ID 85:
The maximum number the thread restarts has been reached and the Microsoft
Exchange Connector for Lotus cc:Mail will be shutdown. Try restarting the
Microsoft Exchange Connector for Lotus cc:Mail service.
The file created by Export contains an illegal section name that is not
handled properly by the CCMC.
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 5.0.
This problem has been corrected in the latest U.S. Service Pack for
Microsoft Exchange Server version 5.0. For information on obtaining the
Service Pack, query on the following word in the Microsoft Knowledge
Base (without the spaces):
S E R V P A C K
Keywords : kbbug5.00 kbfix5.00.sp2 XFOR
Version : 5.0
Platform : winnt
Issue type : kbbug