XFOR: Correlation Table Cleanup Fails; Ct2.dat & Ct2.idx Grow to Large SizeID: Q191773
|
The Linkage 3.2 Directory Exchange (LDE) (or Exchange 5.5 Connector for PROFS or SNADS) correlation table (CT) maintenance routine, CTCLEANUP, may fail to purge the CT files of expired entries. The \linkage\tables\Ct2.dat and Ct2.idx files may continue to grow to a large size. Additionally, the following may be logged in the Linkage Administrator Log browser:
1998/07/22 16:53:22- LME-PROFS-MEXDIA(006f) 3
00504:LME-PROFS-MEXDIA started >> stdmain(878)
1998/07/22 16:55:00- LME-PROFS-MEXDIA(006f) 3 40740:Removing
correlation table records older than 7 day(s) >> ct2(1768)
1998/07/22 16:55:00- LME-PROFS-DIAMEX(01cf) 3 40740:Removing
correlation table records older than 7 day(s) >> ct2(1768)
**** Next 2 entries significant ****
1998/07/22 16:55:00- LME-PROFS-DIAMEX(01cf) 1 40720:Error
{CT:160()} finding correlation table record >> ct2(1078)
1998/07/22 16:55:00- LME-PROFS-DIAMEX(01cf) 1 40750:Error {I/O
error has occurred} scanning correlation table records >> ct2(1874)
1998/07/22 16:55:00- LME-PROFS-DIAMEX(01cf) 3 40741:Correlation
table cleanup is complete: {Successful} >> ct2(1792)
1998/07/22 16:55:00- LME-PROFS(021d) 3 10100:Scheduled event
CTCLEANUP is starting (running time: 0 minutes, restart delay: 0
minutes) >> control(760)
1998/07/22 16:55:00- CONTROL-SERVICE(022b) 3 10100:Scheduled event
CTCLEANUP is starting (running time: 0 minutes, restart delay: 0
minutes) >> control(760)
1998/07/22 16:55:00- LME-PROFS-MEXDIA(006f) 1 40720:Error
{CT:160()} finding correlation table record >> ct2(1078)
1998/07/22 16:55:00- LME-PROFS-MEXDIA(006f) 1 40750:Error {I/O
error has occurred} scanning correlation table records >> ct2(1874)
1998/07/22 16:55:00- LME-PROFS-MEXDIA(006f) 3 40741:Correlation
table cleanup is complete: {Successful} >> ct2(1792)
1998/07/22 16:55:00- LDE(014a) 3 10100:Scheduled event CTCLEANUP
is starting (running time: 0 minutes, restart delay: 0 minutes) >>
control(760)
NOTE: This may also be an issue for the Linkage 3.2 Exchange SNADS
Connector, because CTCLEANUP is a routine common to that connector.
Two circumstances result in this problem:
Obtain the hotfix mentioned below. After obtaining the hotfix, perform the
following steps:
Microsoft has confirmed this to be a problem in Linkage Message Exchange
version 3.2.
A supported fix is now available, but has not been fully regression-tested
and should be applied only to systems experiencing this specific problem.
Unless you are severely impacted by this specific problem, Microsoft
recommends that you wait for the next service pack that contains this fix.
Contact Microsoft Product Support Services for more information.
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 5.5.
A supported fix is now available, but has not been fully regression-tested
and should be applied only to systems experiencing this specific problem.
Unless you are severely impacted by this specific problem, Microsoft
recommends that you wait for the next service pack that contains this fix.
Contact Microsoft Product Support Services for more information.
The correlation table is a mechanism used to track message acknowledgments
from OV/VM and SNADS. By default, the CT holds entries for seven days. If
an entry is older than seven days, CTCLEANUP purges the entry from the
table. All data for the CT is stored in the Ct2.dat file, and its index is
Ct2.idx.
Connector message flow stops while CTCLEANUP is running; thus the CTCLEANUP
routine is only scheduled to run once a day by default. Even if CTCLEANUP's
schedule is modified to run more than once a day, the purge routine within
CTCLEANUP will not run if the timestamp of the zero byte file \table\CT2
(no extension) is the current day.
Keywords : XFOR
Version : 5.5, Linkage 3.2
Platform : winnt
Issue type : kbbug
Last Reviewed: May 25, 1999