XCON: IMS Does Not NDR Message When Passed DISP_NDR_ORIGID: Q178378
|
The Microsoft Exchange Server Internet Mail Service does not send a non-
delivery report (NDR) on a message it has passed from a custom routing .Dll
file with DISP_NDR_ORIG. The message may be delivered to the mailbox and
the following event ID recorded:
Event id 2078 from MSExchangeIS Private
Category: Transfer Out Of Gateway
Description: Unable to submit, send or transfer out a message. Check
PR_DELIVERY_TIME, PR_NDR_REASON, PR_NON_DELIVERY_DIAGNOSTIC.
The Microsoft Exchange Server Internet Mail Service will attempt to resolve the name and deliver the message if a valid address is available in the message. If the address in the recipient list is not valid, the message transfer agent (MTA) will send an NDR. If the address is resolved, then the MTA will attempt to deliver the message.
Microsoft has confirmed this to be a problem in Microsoft Exchange Server version 5.0. This problem has been corrected in the latest U.S. Service Pack for Microsoft Exchange Server version 5.0. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C KMicrosoft has confirmed this to be a problem in Microsoft Exchange Server version 5.5. This problem has been corrected in the latest U.S. Service Pack for Microsoft Exchange Server version 5.5. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: imc ims
Keywords : kbbug5.00 kbfix5.00.sp2 XCON
Version : WinNT:5.0,5.5
Platform : WINDOWS
Issue type : kbbug
Last Reviewed: March 19, 1999