XFOR: PCMTA Tries to Dial Up Asynchronous Connection for Downstream PostofficesID: Q197182
|
The Microsoft Mail Connector (PC) message transfer agent (MTA) incorrectly attempts to establish a dial-up connection for downstream Microsoft Mail postoffices, even though it was not configured to do so.
To work around this problem, create two Microsoft Mail (PC) MTA instances: an Asynchronous and LAN type for connecting PO1, and a LAN type for connecting PO2.
Microsoft has confirmed this to be a problem Exchange Sever 5.0 and 5.5.
Given the following setup:
The Exchange Server computer has two Microsoft Mail (PC) postoffices
connectedly directly to it, one via the LAN, the second one via an
asynchronous connection. The first Microsoft Mail (PC) postoffice also has
a direct connection to a third Microsoft Mail (PC) postoffice via a direct
asynchronous connection.
Additional query words: dialup, DUN, msmail, PCMTA, downstream
Keywords :
Version : WINNT:5.0,5.5
Platform : winnt
Issue type : kbprb
Last Reviewed: May 13, 1999