XFOR: How to Capture and Replay Messages Through the PROFS ConnectorID: Q220833
|
As part of the troubleshooting steps for the Exchange OV/VM (PROFS) Connector, it may be required to capture messages sent from the host to Exchange Server, and subsequently reproduce the same problem locally. This article describes an undocumented feature of the OV/VM Connector included with Microsoft Exchange Server 5.5 Service Pack 2.
debug = Yes
NJE Server or LME-PROFS-NJE
xfmload -nLME-PROFS-VMDIA -pCONTROL-SERVICE -i njeXXXX.datwhere XXXX represents the sequential ordering of each archived file.
C:\exchsrvr\CONNECT\exchconn>xfmload -nlme-profs-vmdia -pcontrol-service -i nje0
000.dat
17:37:57- 3 00504:lme-profs-vmdia started
> stdmain(883)
entering xfmlServEventTimer
exiting xfmlServEventTimer
entering xfmlServEventTimer
exiting xfmlServEventTimer
max ru size specified in CT record is 1024
entering xfmlServEventTimer
nje0000.dat files not found...continuing
exiting xfmlServEventTimer
17:38:27- 2 00500:An ABNORMAL SHUTDOWN request has been received
> stdmain(920)
17:38:27- 2 01108:Event server-lsnje.f-1.r has been destroyed, but is still registered with the event manager
> evtsem(335)
C:\exchsrvr\CONNECT\exchconn>