Remedy Help Desk Notifier Causes GP Fault in Module Tirpc.dllID: Q219008
|
When you start the Notifier tool included with Remedy Help Desk after you upgrade to Internet Explorer 5, you may receive the following error message:
NOTIFIER caused a general protection fault in module TIRPC.DLL at 0001:00004a94.
This error message is caused by an increase in the amount of stack space used by Wininet.dll in Internet Explorer 5. Because Notifier is a 16-bit Windows-based program, it cannot account for this additional stack space usage. This causes a stack overflow.
To resolve this issue, add a "NOTIFIER=0x400000" line to the [Compatibility] section of the Win.ini file:
Additional query words:
Keywords : kb3rdparty kberrmsg gpf msiew98
Version : WINDOWS:5