PRJ98: Project Stops Responding Saving Baseline in PERT View

ID: q174370


The information in this article applies to:


SYMPTOMS

In Microsoft Project 98, if you save a baseline or interim plan while in PERT view, you will receive the following error message:

Windows 95

This program has performed an illegal operation and will be shut down. If the problem persists, contact the program vendor.
If you click Details, you receive an error message similar to the following:
WINPROJ caused an invalid page fault in module WINPROJ.EXE at 0137:302b54dc.

Windows NT

An application error has occurred and an application error log is being generated.

Winproj.exe
Exception access violation (oxc0000005), address: ox3000429ob


CAUSE

These errors occur if you save a baseline or interim plan while in PERT view.


WORKAROUND

To work around this problem, switch to another view before you save the baseline or interim plan.


STATUS

Microsoft has confirmed this to be a problem in the versions of Microsoft Project listed above.

This problem was corrected in Microsoft Project 98 for Windows, Service Release 1 (SR-1).

For additional information about obtaining and installing SR-1, please see the following article in the Microsoft Knowledge Base:

ARTICLE-ID: Q185102
TITLE : PRJ98: How to Obtain and Install MS Project 98 SR-1


MORE INFORMATION

Additional query words: ipf crash


Keywords          : kbusage projwin 
Version           : WINDOWS:98
Platform          : WINDOWS 
Issue type        : kbbug 

Last Reviewed: July 19, 1999