ACC97: More Than One Synch Displayed on Status Bar

ID: Q201222


The information in this article applies to:


SYMPTOMS

Moderate: Requires basic macro, coding, and interoperability skills.

When you run the Replication Synchronizer installed either with the Office Developer Edition or with a run-time application, the status bar text that typically reads "Synchronizer" may be changed to read "More than one Synch."


CAUSE

You have installed the updated Jet 3.51 DLLs on a computer that previously was running Access 97 and you are using the Synchronizer (mstran35.dll) for Replication.

In this case, mstran35.dll is still version 3.50 and does not match the new msrepl35.dll (version 3.51). This causes the caption on the Synchronizer, which normally displays "Synchronizer" on the status bar, to display "More than one Synch."

Note: There are no known adverse affects to this condition.


STATUS

Microsoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article.


MORE INFORMATION

Steps to Reproduce Problem

  1. Install Microsoft Access 97.


  2. Install Microsoft Office Developer Edition.


  3. Install the Jet 3.51 update.


  4. Start the Microsoft Replication Synchronizer.


Note that the status bar text has changed from "Synchronizer" to "More than one Synch."


REFERENCES

For information on how to obtain Microsoft Jet 3.51, please see the the following article in the Microsoft Knowledge Base:

Q172733 ACC97: Updated Version of Microsoft Jet 3.5 Available on MSL
You can also find this information online at the following address:
http://support.microsoft.com/support/kb/articles/Q172/7/33.asp

Additional query words: pra prb


Keywords          : kbdta 
Version           : WINDOWS:97
Platform          : WINDOWS 
Issue type        : kbprb 