ACC97: Query Design Changes Cause Synchronization Error
ID: Q193208
|
The information in this article applies to:
SYMPTOMS
Advanced: Requires expert coding, interoperability, and multi-user skills.
When you use internet indirect synchronization, you my receive the
following error message:
The synchronization failed because a design change could not be applied
to one of the replicas.
-or-
When you use indirect synchronization between two synchronizers, you may
receive the following error messages.
On the machine initiating the synchronization:
The requested synchronization between <local replica path and file
name> and <target server name> is complete, but a problem occurred
during synchronization. For more information, open <local replica
path and file name>, right click on <target server name> on the map,
and click view synchronization history.
-and-
In the Replication Design Errors dialog box, Design Error text box on
the synchronization target machine:
You don't have the necessary permissions to use the <Query name>
object. Have your system administrator or the person who created this
object establish the appropriate permissions for you.
CAUSE
You may receive these error messages under the following conditions:
- You have created or modified a replicable query that has the With
OwnerAccess Option set to True.
-and-
- You are using indirect or internet synchronization.
Direct synchronization does not cause this error.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Access 97.
MORE INFORMATION
Steps to Reproduce Behavior By Using Indirect Internet Synchronization
- Create a replica database containing a query that uses the With
OwnerAccess Option (Run Permissions = Owner's).
- Use Replication Manager to manage the replica on an internet/intranet
server.
- Create another replica on a remote computer.
- From the remote computer, use internet synchronization. The
synchronization should be successful.
- In the Design Master, make a change to the query you created in step 1.
- Synchronize with the replica managed on the internet server (if that is
not the Design Master).
- From the remote computer, use internet synchronization. The
synchronization should fail and you should receive the error messages
mentioned in the "Symptoms" section.
NOTE: If you synchronize directly using these same replicas, the