DOCUMENT:Q174102 15-MAY-1999 [exchange] TITLE :XFOR: Messages Not Flowing from OV/VM to Exchange PRODUCT :Microsoft Exchange PROD/VER:WinNT:4.0,5.0 OPER/SYS: KEYWORDS:kbusage ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft Exchange Server, versions 4.0, 5.0 ------------------------------------------------------------------------------- SYMPTOMS ======== You find that messages are not flowing from OV/VM to Exchange through the LinkAge Exchange-OV/VM (or LinkAge PROFS) Connector and you get the following error messages in the Application Event log: The description for Event ID ( 1 ) in Source ( LSIControl ) could not be found. It contains the following insertion string(s): ENS, 1997/09/05 03:15:37- LME-PROFS-DIAMEX(01e8) 1 40720:Error {CT:160()} finding correlation table record. -and- The description for Event ID ( 1 ) in Source ( LSIControl ) could not be found. It contains the following insertion string(s): ENS, 1997/09/05 03:15:37- LME-PROFS-DIAMEX(01e8) 1 04065:Critical error: Queue item handle passed to QMMarkQItemBad is invalid. You will also find that the OV/VM to Exchange Transform process is not running, and you see the following messages in the Linkage Browse log: LME-PROFS-DIAMEX 40720: Error {CT:160()} finding correlation table record LME-PROFS-DIAMEX 56074: {I/O error has occurred}: Could not find CT record for '1997090310234541 server.org ' LME-PROFS-DIAMEX 04065: Critical error: Queue item handle passed to QMMarkQItemBad is invalid LME-PROFS-DIAMEX 00514: A RESTART request has been received LME-PROFS-DIAMEX 00505: LME-PROFS-DIAMEX is ending, last return code was {A shutdown request was made} CAUSE ===== A possible cause may be a corrupted correlation table. WORKAROUND ========== To work around this problem, do the following: 1. Stop the Linkage Controller service. This will stop the OV/VM Connector and the SNADS Connector (if present). 2. Move the Ct2.idx, Ct2.dat, and Ctlock.dat files from the c:\linkage\tables directory into a backup directory. 3. Delete the Ct2.idx, Ct2.dat, and Ctlock.dat files (the Ctlock.dat file may not be present) from the c:\linkage\tables directory. 4. Restart the LinkAge Controller and Connector services. The correlation tables will be rebuilt. NOTE: There are no tools available that will repair a damaged correlation table; currently rebuilding the table is the only known fix for this issue. Damaged correlation tables (the files that make up the correlation tables) should be sent to Microsoft Support for cause analysis through the normal channels. ====================================================================== Keywords : kbusage Technology : kbExchangeSearch kbExchange500 kbExchange400 kbZNotKeyword2 Version : WinNT:4.0,5.0 Solution Type : kbfix ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 1999.