SYMPTOMS

After installing InstallSHIELD SDK Edition from Microsoft Visual C++ version 4.0, you may see the following error message when you try to run the Template application:

Setup requires a different version of Windows. Check to make sure that you are running Setup on the Windows platform for which it is intended.

Error 102.


CAUSE

The message occurs when a the _inst32i.ex_ does not exist in the directory where Setup.exe is located.


RESOLUTION

To correct the problem in both the Template application and in projects created with InstallSHIELD SDK Edition, copy _inst32i.ex_ from the \Ishield\Disk1 directory on the Visual C++ compact disc into the following two locations on the hard drive:


   \Program Files\Stirling\InstallShield\Program

   -and-

   \Program Files\Stirling\InstallShield\Template\One\Disk1 


STATUS

This behavior is by design.


MORE INFORMATION

This behavior occurs only when InstallSHIELD is installed from Microsoft Visual C++ version 4.0. It does not occur when InstallSHIELD is installed from the Microsoft Win32 SDK.

Additional query words: 4.00


Keywords          : kbsetup ishield 
Version           : 4.00 | 3.51
Platform          : NT WINDOWS 
Issue type        : 

Last Reviewed: March 5, 1999