DOCUMENT:Q116158 26-SEP-1999 [win3x] TITLE :RAS Server Resets in Answer Mode with Sportster Modem PRODUCT :Microsoft Windows 3.x Retail Product PROD/VER:WINDOWS:3.11 OPER/SYS: KEYWORDS: ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft Windows for Workgroups version 3.11 ------------------------------------------------------------------------------- Microsoft does not encourage nor support user changes to .INF files; therefore, Microsoft Product Support Services (PSS) does not support the procedure in this article. Although we have tested the following procedure and it appears to function as described; we strongly recommend that you make a backup copy of your .INF file before you proceed. SYMPTOMS ======== When Remote Access Services (RAS) is placed in answer mode with a U.S. Robotics 14400 Internal Sportster modem, the modem may stay in a continuous loop between "Waiting for Call" and "Device Reset." This issue occurs only when the device is placed in answer mode with the RAS point-to-point server. RESOLUTION ========== To correct this problem, edit the modem initialization entry (COMMAND_INIT=) in the [US Robotics Sportster 14400] or [US Robotics Courier V.32bis] section of the MODEM.INF file as follows: 1. Run Microsoft Windows for Workgroups Write and open the MODEM.INF file. 2. Choose the No Conversion button. 3. From the Find menu, choose Find. 4. In the Find What box, type "[US Robotics Sportster 14400]" (without the quotation marks) or "[US Robotics Courier V.32bis]" (without the quotation marks) and then choose Find Next. 5. Choose Cancel and then change "AT&F" (without the quotation marks) to "ATZ&F" (without the quotation marks). For example, change COMMAND_INIT=AT&F&C1&D2 V1 S0=0 S2=128 S7=55 W1 S95=44 to: COMMAND_INIT=ATZ&F&C1&D2 X7 V1 S0=0 S2=128 S7=55 W1 S95=44 6. Save the MODEM.INF file. 7. Quit and restart RAS Phonebook. This issues a reset command that resets the modem to the factory defaults. The X command setting establishes compatibility with older modems that send different result codes to the receiving modem. X7 is used to enable result codes 0-11 and 13-43, which are used mainly on U.S. Robotics modems. Check the BIOS date of the modem and then check with the modem manufacturer to determine the current modem BIOS date available. Additional query words: 3.11 hardware failure errors gateway 2000 point to ptp 3rdparty usr ====================================================================== Keywords : Technology : kbAudDeveloper kbWFWSearch kbWFW311 Version : WINDOWS:3.11 ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 1999.