DOCUMENT:Q99578 30-JUL-2001 [lanman] TITLE :Trap Errors with NEC Powermate Global Cache and Madge PRODUCT :Microsoft LAN Manager PROD/VER: OPER/SYS: KEYWORDS: ====================================================================== SYMPTOMS ======== Your system traps with an NEC Powermate 486 EISA tower with global cache turned on, and a Madge 32-bit token ring card. CAUSE ===== Madge token ring card models other than 5208 (part number series 95XXX) cannot function with the NEC CMOS global cache setting turned on. Any other Madge token ring card model (5209, 5210, and so on) traps the system. WORKAROUND ========== Turn the NEC CMOS global cache off or obtain Madge token ring card model 5208. Additional query words: globalcache 2.20 2.2 madge5208 ====================================================================== Keywords : ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2001.