DOCUMENT:Q179467 05-APR-2000 [sna] TITLE :Inappropriate Use of Trailing FILLER with an Array PRODUCT :Microsoft SNA Server PROD/VER:WINDOWS:1.0 OPER/SYS: KEYWORDS: ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft COM Transaction Integrator for CICS and IMS, version 1.0 ------------------------------------------------------------------------------- SYMPTOMS ======== A parameter with trailing bytes of FILLER specified is declared as an array. The specified amount of FILLER follows the array as a whole, rather than each element of the array, as might be expected. This can be demonstrated by exporting COBOL statements from this component. CAUSE ===== You can use Component Builder (CB) to specify that a parameter, declared as an array, has trailing bytes of FILLER. Trailing FILLER is declared with the COBOL Definition tab of the parameter's Properties page. (Arrays are declared with the Arrays tab.) The number of bytes of FILLER to be transmitted From Host or To Host (or both) are also specified. This implies that a COMTI run-time version would treat it like the following example in COBOL: 10 GROUP-ARRAY OCCURS y TIMES. 15 ELEMENT PIC x. 15 FILLER PIC x. However, run-time version actually treats it as the following COBOL: 10 ELEMENT PIC x OCCURS y TIMES. 10 FILLER PIC x. In other words, the FILLER will trail the array, rather than each element of the array. WORKAROUND ========== If you do have an array and each element has FILLER following it, then the item description must be treated as a recordset with one column. Declare a recordset with the element and its trailing FILLER. Declare the parameter with the recordset as its data type. Then set the parameter's array properties. You can also use the COBOL Import Wizard, which correctly handles importing either of the above COBOL samples. STATUS ====== Microsoft has confirmed this to be an issue in Microsoft COM Transaction Integrator for CICS and IMS, version 1.0. It is not a bug. You must be aware of the circumstances under which this behavior occurs because it relates to the accurate disposition of data both to and from the mainframe server application. Additional query words: ====================================================================== Keywords : Technology : kbAudDeveloper kbCOMTISearch kbCOMTI100 Version : WINDOWS:1.0 Hardware : ALPHA x86 Issue type : kbprb Solution Type : kbpending ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2000.