DOCUMENT:Q230601 06-AUG-2002 [sna] TITLE :CB Incorrectly Maps COBOL Data Types for Unsigned Display PRODUCT :Microsoft SNA Server PROD/VER:WINDOWS:4.0 SP2 OPER/SYS: KEYWORDS:kbsna400sp3fix ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft SNA Server, version 4.0 SP2 - Microsoft COM Transaction Integrator for CICS and IMS, version 4.0 SP2 ------------------------------------------------------------------------------- SYMPTOMS ======== Method parameters defined using automation types of Integer, Long, Single, Double, Currency, or Decimal are incorrectly mapped to COBOL data type of type PIC 9(n) LEADING SEPARATE DISPLAY (or PIC 9(n)V9(n)LEADING SEPARATE DISPLAY) in Component Builder (CB) when you build new COM Transaction Integrator (COMTI) components. The first indication this problem exists may be a run time error. The first indication of the possibility of this problem is a run time error. The following error message is posted to the Windows NT application event log: Event ID: 102 Source: COMTI Type: Error Category: General (102) COM Transaction Integrator reported the following exception to the client: Component: Method: Exception description: (1562) Parameter in method contained an invalid zoned decimal value. Check the mainframe server program. If it is correct, verify that the correct COM Transaction Integrator-created component library is deployed. EXPLANATION An Automation exception representing an error condition was returned to a COM Transaction Integrator client. The description shown above contains more information about the exception that was reported. Because this error message may accurately indicate a problem of the application code, a further step is necessary to demonstrate a COMTI problem exists instead. Export COBOL from the COMTI component library. You can see the variables in question defined with the "LEADING SEPARATE DISPLAY" attribute. CAUSE ===== COMTI is not handling the conversion properly for unsigned DISPLAY. RESOLUTION ========== To resolve this problem, obtain the latest service pack for SNA Server version 4.0. For additional information, click the following article number to view the article in the Microsoft Knowledge Base: Q215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack STATUS ====== Microsoft has confirmed that this is a problem in Microsoft SNA Server version 4.0SP2. This problem was first corrected in SNA Server version 4.0 Service Pack 3. Additional query words: ====================================================================== Keywords : kbsna400sp3fix Technology : kbAudDeveloper kbSNAServSearch kbCOMTISearch kbCOMTI400SP2 kbSNAServ400SP2 kbComSearch Version : WINDOWS:4.0 SP2 Issue type : kbbug Solution Type : kbfix ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2002.