DOCUMENT:Q255173 13-JUN-2001 [sna] TITLE :Applet Stop Responding When Connecting with TN3270E PRODUCT :Microsoft SNA Server PROD/VER:WINDOWS:3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3 OPER/SYS: KEYWORDS:kbSNA400sp4fix kbSNA400PreSP4fix ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft SNA Server, versions 3.0 SP1, 3.0 SP2, 3.0 SP3, 3.0 SP4, 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3 ------------------------------------------------------------------------------- SYMPTOMS ======== When a user tries to connect a TN3270E session using the 3270 Applet included with SNA Server, the applet may stop responding with a blank screen. The Status bar shows Connected. At this point, the applet is locked, and the only way to close the session is to end the task using Task Manager. This problem only occurs when the 3270 Applet is configured in TN3270E mode. CAUSE ===== When the BIND sent from the host specifies a Max Request Unit (RU) size of 0 for the primary half-session, the 3270 Applet moves into a tight loop while processing the BIND. RESOLUTION ========== To resolve this problem, obtain the latest service pack for SNA Server 4.0. For additional information, please see the following article in the Microsoft Knowledge Base: Q215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack STATUS ====== Microsoft has confirmed this to be a problem in SNA Server versions 3.0 (all SP), 4.0, 4.0SP1, 4.0SP2, and 4.0SP3. This problem was first corrected in SNA Server 4.0 Service Pack 4. MORE INFORMATION ================ The following excerpt from an SNA Server message trace shows a BIND sent from the host specifying an RU size of 0 for the primary half-session: DLC 07160000->01020101 DLC DATA DLC DAF:02 OAF:01 ODAI:off Exp. DLC BIND RQD SC FI BC EC DR1 DLC DLC ---- Header at address 01204688, 1 elements ---- DLC 01020000 00002D00 02012757 01006C06 ......-...'W..l. DLC DLC ---- Element at address 01BF0EDC, start 10, end 49 ---- DLC 6B800031 010303B1 B0308000 00850000 k..1.....0...e.. DLC 00028000 00000000 00000002 000008D9 ...............R DLC E3D6E3C1 D3C4E500 TOTALDV. Bytes 10 and 11 (where Byte 0 is X'31') in this BIND are defined as X'8500'. These are the bytes that specify the RU sizes for the secondary and primary half-sessions, respectively. When the primary half-session Max RU size is 0, the applet gets into a tight loop when it receives the BIND Image in TN3270E mode. The updated TN3270.DLL corrects the problem in the applet. Also, if the BIND is changed so that Byte 11 is not 0, the problem does not occur. Third-party emulators may also experience this problem, and it may be necessary to upgrade to a newer version. Please refer to the vendor of the emulator for more information. Additional query words: ====================================================================== Keywords : kbSNA400sp4fix kbSNA400PreSP4fix Technology : kbAudDeveloper kbSNAServSearch kbSNAServ400 kbSNAServ300SP3 kbSNAServ300SP1 kbSNAServ400SP1 kbSNAServ400SP2 kbSNAServ400SP3 kbSNAServ300SP2 kbSNAServ300SP4 Version : WINDOWS:3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3 Issue type : kbbug Solution Type : kbfix ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2001.