Unable to Load Ontciutl.dll

ID: Q193175


The information in this article applies to:


SYMPTOMS

The following event message occurs in the Event Viewer:


   EventId: 7034
   Unable to load DLL %SYSTEMDRIVE%\Program Files\Common
   Files\SYSTEM\ContentIndex\ontciutl.dll>. Error: 5 - Access is
   denied. 


CAUSE

The LAN Manager redirector cannot reliably query for the existence of a file on a universal naming convention (UNC) path. The UNC path is a directory path that contains a file share access to a certain server that is compliant with the Microsoft network. An example of a UNC path is as follows:

\\myserver\myshare


WORKAROUND

  1. If possible, remove the UNC path in the SYSTEM and USER path variables.
    -or-
    If this is not possible, add the location %SYSTEMDRIVE%\Program Files\Common Files\SYSTEM\ContentIndex to the SYSTEM path BEFORE any UNC path variables.


  2. Restart the computer. SYSTEM variables are loaded on system startup.



STATUS

Microsoft has confirmed this to be a problem in Site Server version 3.0.

Additional query words: kbecu


Keywords          : prodsitesrv3 prodsrch 
Version           : WINNT:3.0
Platform          : winnt 
Issue type        : kbbug 

Last Reviewed: July 20, 1999