PRJ98: Setup Error: Setup could not find the file...MSSP232.dll

ID: q178685


The information in this article applies to:


SYMPTOMS

When you install Microsoft Project 98 from an Administrative Installation Point on a server, you may receive the following error message

Setup could not find the file "\\<server>\<share>\<directory Project98 setup is located>\OS\MSAPPS\PROOF\MSSP232.DLL
followed by the error message:
Setup could not find the file "\\<server>\<share>\<directory Project98 setup is located>\OS\MSAPPS\PROOF\MSSP2_EN.LEX
When you click the Ignore button, Setup will continue and Project will be able to run, but the Spelling tool will not work.


CAUSE

During the Administrative installation of Microsoft Project 98, you chose either Local or User's choice for the shared tools location. The error messages described in the SYMPTOMS section may occur when installing Project from that Administrative Installation Point. The setup program is looking for the spelling checker files in the wrong location.


WORKAROUND

To resolve this problem, follow these steps:

  1. On the Workstation on which you installed Microsoft Project 98 and on which you received the errors messages, remove the Project Workstation installation. To do so, follow these steps:


    1. Click the Start button, point to Settings, and click Control Panel.


    2. Double-click the Add/Remove Programs icon, click the Install/Uninstall tab, select Microsoft Project 98, and click the Add/Remove button.


    3. When prompted, click the Remove All button.


  2. On the Microsoft Project 98 Administrative Installation point on the server, copy the PROOF folder (this will copy the files noted in the error message) from the following folder
    \MSAPPS
    to:


  3. \MSOFFICE\OS\MSAPPS
  4. Rerun the Workstation install. It will now be able to find the files listed in the error messages.


NOTE: The default directories created during the Administrative installation are \MSAPPS and \MSOffice. An additional MSAPPS folder is located under the folder \MSOffice\OS.

NOTE: After performing an Administrative installation, permissions for the installation point on the server should be set to Read Only. If users have Write permissions to the installation point, changes may be made that will impact all users of that intallation point.


STATUS

This problem was corrected in Microsoft Project 98 for Windows, Service Release 1 (SR-1).

For additional information about obtaining and installing SR-1, please see the following article in the Microsoft Knowledge Base:

ARTICLE-ID: Q185102
TITLE : PRJ98: How to Obtain and Install MS Project 98 SR-1

Additional query words: setup error mssp2_en.lex mssp232.dll


Keywords          : projwin 
Version           : WINDOWS:98
Platform          : WINDOWS 
Issue type        : kbbug 

Last Reviewed: July 16, 1999