PRJ98: Resource Peak Units May Be Displayed Incorrectly

ID: q189878


The information in this article applies to:


SYMPTOMS

In Microsoft Project 98, resource Peak Units may display incorrectly in a resource view.

For example, time-phased resource Peak Units for a period may be blank even though the resource has assignments for that period.


CAUSE

This behavior occurs when multiple assignments for a single resource for the same time period exceed the Microsoft Project limit of 10,000 units (1,000,000 per cent) for a single resource assignment.


RESOLUTION

To correct this problem, install Microsoft Project 98 for Windows Service Release 1 (SR-1). Resource units will not be displayed incorrectly when multiple assignments for a single resource for the same time period exceed the Microsoft Project limit of 10,000 units (1,000,000 per cent) for a single resource assignment.


STATUS

This problem was corrected in Microsoft Project 98 for Windows, Service Release 1 (SR-1).


For additional information about obtaining and installing SR-1, please see the following article in the Microsoft Knowledge Base:

Q185102 PRJ98: How to Obtain and Install MS Project 98 SR-1


MORE INFORMATION

If the sum of all assignments exceeds the 10,000 limit for any period, the time-phased resource Peak Units field for that period in the Resource Usage view will be blank, and the resource Peak field on a resource table will display as 1.

Additional query words:


Keywords          : projwin 
Version           : WINDOWS:98
Platform          : WINDOWS 
Issue type        : kbbug 

Last Reviewed: July 27, 1999